New Technology for Clinical CT Scans – Imaging Technology News


Prototype of a clinical CT device combines dark-field X-ray and conventional technology
Design of the human-scale dark-field CT system. (A) Layout of the Talbot–Lau interferometer integrated into a conventional medical CT system. Bent gratings in an inverse geometry allow positioning of G0 and G1 close to the source. A large G2 is positioned close to the detector. Contrast formation is illustrated in SI Appendix, Fig. S1. (B) CT gantry equipped with a Talbot–Lau interferometer. The large G2 covering the detector is visible, while the G0 and G1 fixture is concealed by the collimator box. A human chest phantom is positioned on the patient couch. (C) Parameter analysis for rectangular and triangular G1 gratings. A maximum performance (i.e., fringe visibility) is expected for a duty cycle of 0.5 and 18.5μm18.5 μm in height for a triangular profile. (D) Simulation shows that performance is highly parameter dependent. Small deviations in G1 periodicity in the nanometer range or in length L in the millimeter range cause irreversible performance loss. (E) A specialized G0 and G1 fixture to bend gratings to focus into the X-ray source spot. Rigid mounting is important to ensure stability during continuous rotation at high centrifugal forces. (F) Stitched G2 using a modular adjustment frame to individually position a total of 13 tiles. Fine position and rotation manipulation as well as long-time stability during rotation are key aspects of this component (SI Appendix, Fig. S2). Image courtesy of PNAS
February 9, 2022 — For the first time, a team of researchers at the Technical University of Munich (TUM) has integrated the dark-field X-ray method into a CT scanner suitable for clinical use. Dark-field imaging provides additional information to conventional X-ray imaging. With the new prototype, it is now possible to produce three-dimensional dark-field X-ray images.
Computed tomography (CT) is one of the most important clinical methods for precise and fast diagnostics. By combining multiple X-ray images three-dimensional images of the patient are generated. With dark-field imaging now additional information on fine tissue structures, in particular in the lung, is accessible. Until now, technical challenges have prevented the integration of this new technology into clinical CT scanners to examine patients.
A team of researchers working with Franz Pfeiffer, Professor for Biomedical Physics and Director of the Munich Institute of Biomedical Engineering at TUM, has now developed a CT scanner that combines both X-ray technologies.
“For the first time, we showed that dark-field X-ray technology can also be integrated into a clinical CT scanner. Although this technology is in its early stages, pre-clinical studies with mice have demonstrated clear benefits from dark-field CT scans, especially for capturing images of lung tissue,” says Franz Pfeiffer, who headed the study. The new CT prototype has already been used successfully with a thorax phantom, a model of a human upper body, and is large enough for the intended applications with real patients.
With conventional X-ray equipment, the X-rays are attenuated by the intervening tissue as they travel from the source to the detector. This effect is used to produce images based on the varying degrees of attenuation associated with different tissue types and structures. That is why bones and similar structures, which have a stronger attenuating effect, appear white in X-rays, while more transparent tissue types such as the lung produce darker images.
Dark-field imaging, by contrast, makes use of the small-angle scattering of the X-rays. When the X-rays interact with materials of different densities such as the interface between lung tissue and air, they are scattered. The analysis of this scattering effect yields additional information on very fine tissue structures, which is otherwise not accessible with conventional X-ray images.
To detect the scattering of the X-ray radiation, a set of three optical gratings is required. They are placed between the X-ray source and detector. When X-rays pass through these gratings, a characteristic pattern is produced at the detector. When a sample or person is then positioned in the beam path, this characteristic pattern is changed. These deviations are then used to analyze the structure of the sample or the person’s tissue.
The implementation of the dark-field method in a human-size CT scanner poses various technical challenges. Until now, this has limited dark-field CT devices to a scale much smaller than would be needed for human patients. Apart from the size, the fast rotation of the scan unit also creates special difficulties for the technical design.
The scanning unit of CT scanners, known as the gantry, rotates at very high speeds. This causes vibrations that affect the finely-tuned components in the interior of the device. Based on a detailed analysis of these vibrations, the team was able to use them to implement the required shift between the gratings needed for dark-field imaging. To analyze the scans, they developed new algorithms to filter out the vibration effects based on reference scans.
“With the dark-field CT prototype, we can capture conventional and dark-field X-ray images in a single scan. This yields additional information that could be used in the future not only to diagnose lung diseases, but also to differentiate between various types of kidney stones and tissue deposits,” said Manuel Viermetz, one of the two first authors of the study. As the next step, the researchers plan to further optimize the dark-field CT prototype and prepare for the first scans of human patients.
For more information: https://www.tum.de/en/
At RSNA 2021, Fujifilm launched its new Velocity MRI system. It is designed to streamline workflow and enhance the …
February 4, 2022 — The American Roentgen Ray Society (ARRS) announced that Edward Y. Lee, MD, MPH of Boston Children’s …
February 4, 2022 — A new diagnostic tool for breast cancer that combines two ultrasounds has been developed. A POSTECH …
February 3, 2022 — The American Society for Radiation Oncology (ASTRO) issued the following statement from ASTRO Board …
Here is a list of the Top 10 most read pieces of content on ITNonline.com from the month of January 2022. This is based …
February 2, 2022 — Urgent and immediate action must be taken to ensure more effective and equitable implementation of …
February 2, 2022 — The American College of Radiology (ACR) has designated Hackensack Meridian Mountainside Medical …
February 1, 2022 — The Global CT Scanners Market was valued at $7.25 billion in 2020 and is anticipated to grow at an …
Sun Nuclear highlighted two resources for CT Quality Assurance at RSNA 2021. ITN visited their booth to learn more about …
Agfa recently announced the launch of the new Valory digital radiography room, which was designed for health care …
See All Webinars
See All Videos
See All Blogs

See All Comparison Charts

source